The Residential volume of the 9th Edition (2026) Florida Building Code brings over many 2024 IRC changes. These are the ones that will show up most often on house plans, additions and elevated homes.

Stairs, landings and glazing

  • Exterior stairs with three or fewer risers serving a deck, porch or patio can use a 36-inch landing, as long as that door is not the required egress door (R311.7.6).

  • Doors opening from Category I and II sunrooms and screen enclosures onto grass or soil get landing exceptions (R311.3).

  • Nosing tolerances now include the top landing, and open-riser stairs can have nosings over 1¼ inches (R311.7.5.3).

  • Skylights and sloped glazing that meet the stated conditions need retention screens regardless of glass area (R308.6.5).

Smoke and carbon monoxide alarms

  • Smoke alarms are now required in attached garages and in rooms open to a sleeping loft. Listed, interconnected heat detectors can be used where smoke alarms can't be installed per their listing (R314.3).

  • Alarms must be at least 10 feet from permanently installed cooking appliances, with a 6-foot exception (R314.3.1).

  • Battery-only CO alarms need a sealed battery that lasts at least 10 years (R315.1.1).

Fire separation and framing

  • Dwelling-to-garage separation now covers connected spaces such as closets and bathrooms built over the garage (R302.6).

  • Two-family dwellings get separation rules for shared accessory rooms (R302.3.2).

  • Pipes, conduit and cables under roof decks need 1½ inches of clearance, with exceptions (R803.3).

  • Appendix J adds structural requirements for horizontal and vertical additions (AJ701).

Garages, EV chargers and batteries

  • EV chargers must be installed to NFPA 70 and listed to UL 2202 or UL 2594 (R309.7).

  • Automotive lifts must be listed to ANSI/ALI ALCTV and can't go in habitable space (R309.6).

  • Energy storage systems need specific self-closing, self-latching doors into the house, plus vehicle impact protection such as bollards (R328).

Mechanical and plumbing

  • Dryers exhausting more than 200 cfm need makeup air. Closet installations need makeup air per the manufacturer, or 100 square inches of openings if the manufacturer doesn't specify (M1502.6).

  • New provisions for A2L refrigerants follow ASHRAE 15.2 (M1411), and condensate drains in unconditioned space need R-3 insulation.

  • Return air from bathrooms is no longer prohibited (M1602.2).

  • Water heaters must meet NSF 372 lead limits (P2801.9), and GFCI protection follows the 2023 NEC (E3408).

Building near the beach? See New saltwater corrosion and flood rules. Energy changes for homes are in 2026 Florida energy code changes.

Source

Analysis of Changes, 9th Edition (2026) FBC, Residential (Florida Building Commission). This is a plain-language summary of the Florida Building Commission's published Analysis of Changes, not the code itself. Always check the adopted code text and your local building department before you design or permit. Questions about how a change affects your project? Call Voelkel Engineering at 850-288-0333.

 
 
 