What ASCE 7-22 Changed for Wind Loads in the 8th Edition Florida Building Code
The Florida Building Commission’s June 2024 fact sheet, WIND LOADS – IMPACTS FROM ASCE 7-22, explains how the 8th Edition (2023) Florida Building Code updated its wind criteria to match ASCE 7-22.
The 8th Edition FBC, Building and Residential, now references ASCE 7-22, Minimum Design Loads and Associated Criteria for Buildings and Other Structures. The Commission highlights five groups of changes: wind speed maps, roof pressures on slopes greater than 7°, new criteria for elevated buildings, new tornado loads, and a few other updates.
Wind speeds are the part most people notice, and the change is more local than it first sounds. The fact sheet says the ASCE 7-22 maps were revised through most of the hurricane-prone region, but in Florida the speeds changed only in the panhandle. Peninsula speeds are unchanged and, in the Commission’s words, “effectively have not changed since the 2010 FBC.” For Risk Category I, II, and III buildings, speeds increased in the western panhandle. For Risk Category IV, speeds increased in the western panhandle and decreased slightly in the Big Bend.
A new note on Figure 1609.3(1) allows site-specific speeds from the ASCE Wind Design Geodatabase, the ASCE 7 Hazard Tool. The fact sheet also warns that the ATC Hazard by Location website supports ASCE 7-16, 7-10, and 7-05 and will not be updated for ASCE 7-22, so it should not be used for site-specific speeds under the 8th Edition, which took effect December 31, 2023. University of Florida county-level Vult maps exist for all 67 counties, but the fact sheet says those are informational and the local jurisdiction should be contacted for a specific site, because local maps are often modified.
Roof component-and-cladding loads for gable and hip roofs steeper than 7° were revised again. ASCE 7-16 had added more roof zones and raised pressures in many of them. ASCE 7-22 simplifies those roofs back to three zones, truncates the log graphs at 10 square feet, and generally lowers design pressures for many zones. Low-slope roofs (0 to 7°) are unchanged from ASCE 7-16. Some zones are unchanged or slightly higher. Overhang graphs for the steeper roofs were removed; overhang component-and-cladding pressure is now the roof pressure above the overhang plus the adjacent wall pressure, using the effective area of the overhang element.
New provisions cover elevated buildings. Main wind-force resisting system loads are in ASCE 7-22 Section 27.3.1.1. Buildings that meet the geometric limits in that section may use the new elevated-building method. Buildings that do not must be designed as if they sit on the ground, with no wind passing beneath them and the open portion treated as enclosed. Component and cladding loads on the underside are in Section 30.3.2.1 for mean roof heights of 60 feet or less and Section 30.4.2.1 for taller buildings, using modified low-slope roof figures.
New Chapter 32 covers tornado loads. Those provisions apply only to Risk Category III and IV buildings in the tornado-prone region, which includes all of Florida. The Commission points readers to a separate Building A Safer Florida fact sheet for that topic.
Other changes include small adjustments to velocity-pressure coefficients (Kz) in Exposure B at mean roof heights of 40 feet and above and Exposure C at 140 feet and above; deletion of the simplified methods; new wind provisions for ground-mounted solar panels and roof pavers; and expanded canopy criteria for buildings taller than 60 feet.
A later Tampa Bay guide by Judian Duran, PE, restates those Commission findings and notes that the 9th Edition (2026) Florida Building Code is scheduled to take effect December 31, 2026. Which edition governs a project still depends on when the permit application is filed.
Our take
The important Florida map change is not a statewide increase. Peninsula speeds stayed put. The western panhandle, including the Gulf Breeze area where we work, did see higher mapped speeds for Risk Categories I through IV. If someone is still pulling speeds from an older 7th Edition set or from the ATC Hazard by Location site, those numbers are the wrong basis for an 8th Edition permit.
Use the building official’s adopted map or the ASCE 7 Hazard Tool for the address, risk category, and exposure. County PDF maps are a useful check, but they are not a substitute for the local amendment.
The roof-zone simplification is welcome, especially for residential work, but it is not a blanket reduction. Some zones went down, some did not. Overhangs on roofs steeper than 7° now follow a different method, so copied notes from an ASCE 7-16 project can be wrong even when the mapped speed did not change.
The new elevated-building criteria matter for house elevation work. If the building meets the geometric limits in Section 27.3.1.1, use the new method. If it does not, the code does not let you take credit for wind flowing under the house. That is a conservative fallback, and it should be called out early so the owner is not surprised by the loads on the piles, piers, and floor system.
Tornado loads in Chapter 32 are real, but they are not a new requirement for a typical Risk Category II house. They apply to Risk Category III and IV buildings. That distinction is worth keeping clear.
Finally, the 9th Edition is scheduled for December 31, 2026. The edition that governs is the one in effect when the application is submitted, so that date should be confirmed with the building department on any project that will carry into late 2026.


Comments