Do You Need a Soil Report for a Metal Building Foundation? PEMB Geotechnical Guide for Florida, Alabama and Texas
Updated: Nov 20
If you sell or erect pre-engineered metal buildings (PEMBs), one question comes up on almost every job: does this building need a soil report before the foundation can be designed? The honest answer is "it depends," but the factors are predictable. Voelkel Engineering LLC designs sealed PEMB foundations in Florida, Alabama and Texas, working remotely from the manufacturer's reaction package and the site information you already have. This guide explains when a geotechnical report is needed, when the code lets us design without one, and how the choice affects cost and schedule.
Why soil matters so much for metal buildings
A metal building is light, but its foundation works hard. The main frames deliver large horizontal thrust at the base, and under design wind the columns often pull up instead of pushing down. That means the foundation has to do three jobs at once:
Carry gravity loads without exceeding the allowable soil bearing pressure.
Resist uplift, mostly with the weight of concrete and soil above the footing.
Resist frame thrust, usually with hairpins or tie rods into the slab, or with footings sized for sliding.
The soil bearing value drives footing size. A conservative assumed value gives bigger footings and more concrete. A tested value from a geotechnical report can shrink footings, or it can warn us about soft or expansive soil before the slab cracks.
When the code lets us design without a soil report
The International Building Code (IBC), and the Florida Building Code (FBC) that is based on it, include a table of presumptive load-bearing values by soil class. Where the building official accepts it, an engineer may design with those conservative values instead of site-specific test results. For many small and mid-size PEMBs on ordinary sites, such as shops, garages, barns and storage buildings, that is a practical, code-recognized path.
Designing without a report usually makes sense when:
The building is modest in size and the column reactions are moderate.
The site is not known for soft, organic or expansive soils.
The local building department does not require a geotechnical report for this building type or size.
The owner prefers to accept somewhat larger footings in exchange for skipping the cost and wait of a soil investigation.
We state the soil assumptions clearly on the sealed drawings, so the building department and the contractor know exactly what the design is based on.
When you should get a geotechnical report
Some sites and buildings really do need testing. We will recommend a geotechnical report when:
The building department requires one, which is common for larger commercial buildings.
The building is large, tall or heavily loaded, such as cranes, mezzanines or large clear spans with high column reactions.
The site has known problem soils: organic or mucky soils and high groundwater are common in parts of Florida, and expansive clays are common across much of Texas and parts of Alabama.
The site was recently filled, graded or cleared of trees, or has old foundations or debris below grade.
The building sits in a flood zone or near the coast, where scour, saturated soil and high water tables change the design.
Expansive clay deserves special mention for Texas jobs. Clay that swells and shrinks with moisture can heave a slab-on-grade and crack it, regardless of how well the frame is designed. A soil report gives the swell potential and recommended slab and moisture-control measures. Designing a large building on expansive clay without that information is a gamble.
How a soil report changes the foundation design
When a geotechnical report is available, we design to its recommendations: allowable bearing pressure, minimum footing depth, slab subgrade preparation, and any special requirements such as removing and replacing poor soil or using a stiffened or post-tensioned slab. A good report often pays for itself on bigger buildings through smaller footings and fewer surprises during construction.
If you do not have a report, we can still start. We review the site location, the building size and the reactions, and tell you whether a presumptive-value design is reasonable or whether testing is the safer call before you commit to a foundation.
What we need from you for a PEMB foundation design
Because we work remotely, there is no site visit to schedule. Send us:
The metal building manufacturer's reaction package (column reactions for each load case and the anchor bolt layout).
The building drawings or at least the building size, frame spacing, eave height and any mezzanine or crane loads.
The site address, so we can confirm the wind speed, exposure and the jurisdiction's adopted code edition.
The geotechnical report, if you have one, or a note that there is none.
Any slab requirements: thickness preferences, vehicle or equipment loads, and openings or pits.
From that, we deliver sealed foundation drawings and calculations covering footing sizes, anchor bolt embedment and edge distance, uplift and sliding checks, and the frame thrust solution, ready for permit.
Turnaround
Typical turnaround is 5 to 10 business days after we receive a complete reaction package. See our for other starting prices, and our guide to metal building foundation and anchor bolt design for more on how reactions turn into footings.
If you sell metal buildings and want a dependable engineer for repeat foundation packages, ask about setting up a standing workflow so each new job starts with a simple upload of the reaction package.
Get started
Voelkel Engineering LLC is licensed in Florida (CA 35353), Alabama (ECA50016) and Texas (F-22869). Send your reaction package and site address through our contact page or call (850) 288-0333, and we will tell you whether your building needs a soil report before we start the foundation design.